80W / 120W / 150W / 200W
Features / Advantages
The control head Type 8681 is optimized for decentralised automation of hygienic process valves. Thanks to its universal adapter it can be combined with all normal commercial butterfly valves, ball valves, single and double seated valves. With a decentralised automation concept, the control head takes over all pneumatic actuation, feedback and diagnostic functions including fieldbus communication. The housing is easy to clean and features proven IP protection and chemically resistant materials for use in hygienic processing in food, beverage and pharmaceutical industries. Depending on the process valve type, up to 3 pneumatic actuator chambers can be controlled independently from each other. The switching speeds of both movement directions can be set separately. A built-in check valve prevents incorrect switching of process valve actuator chambers which could result from back-pressure. The process valve switching positions are detected by an inductive, analogue position sensor and reported to the PLC system. Up to 3 switching points can be adjusted automatically by a Teach-In function. Additionally a fourth switching position can be read in and fed back via an external inductive proximity switch. The coloured status display signals the particular process valve switching position or indicates a diagnostic function such as maintenance required status or fault conditions. The pilot valves are equipped with a manual override. If the device housing is closed, the patented magnetically encoded manual override tool can be used to open the process valve from the exterior. Bus communication is available with AS-interface, IO-Link or büS/CANopen.
The new thermal flow direction switch VA 409 with direction indication serves for determination of the flow direction of compressed air and gases especially in closed circular pipelines.
By means of VA 409 with flow direction indication the flow direction of the compressed air can be determined quickly and safely. Compared with the former mechanical paddle flow switches VA 409 is able to detect even the smallest changes in the flow direction quickly and without any mechanical movement.
The direction information in form of a potential-free contact (normally closed max. 60 VDC, 0.5 A) is transferred to the consumption sensors VA 500/ VA 520 or to a separate building management system (mbs). Two LEDs show the flow direction.
In connection with 2 consumption sensors VA 500/ VA 520 incoming and outflowing compressed air in closed circular pipelines can be measured precisely.
Details
Recording and reducing energy costs and CO2 emissions while increasing the sustainability of any compressed air system. With our VA500 it is possible to monitor your consumption and analyze your leakage flows with just one measuring device. Due to its design, it is also ideal for mobile measurements.
Details
Record and reduce your energy costs and increase your sustainability with the VA 520. Monitor your consumption and analyze your leakages with a permanently installed flow meter in distribution stations, in front of individual departments or for billing purposes of individual consumers.
Details
Reduce your energy costs and increase your sustainability with the VA 521. Monitor the consumption of each machine and analyze your leakage flows with just one measuring device.
Details
The innovative VA 525 combines modern digital interfaces for connection to an energy monitoring system with a small, compact design. The VA 525 is always used when many machines (compressed air consumers) have to be integrated into an energy monitoring network.
Reduce your energy costs and increase your sustainability with the VA 525 compact sensor. Monitor the consumption of individual machines and analyze your leakage flows with just one measuring device.
Details
Record and reduce your energy costs and increase your sustainability with the VA 550. Monitor your Consumption and analyse your leakage flows with just one measuring device. Due to its design, it is also ideal for Portable Measuring.
Details
Record and reduce your energy costs and increase your Sustainability with the VA 570 flow meter. Monitor your Consumption and analyse your leakage rate with a permanently installed flow meter in distribution stations, in front of individual departments or for billing purposes of individual Consumers.
Details
Reduce your energy costs and increase your efficiency with the VD 500. Suitable directly for measurement after the compressor. Monitor the delivery rate of your compressor and create a FAD analysis.
Details
Details
Details
Details
Details
The high-precision all-rounder. Record and reduce your consumption and increase your sustainability with the VX 570. Monitor your consumption of a wide range of media with just one sensor.
Details
45W / 65W
Features / Advantages Warrior™ FEL-D Area
45W / 65W
Features / Advantages
There are certain applications that push the envelope of existing valve technology – this can be due to extreme temperatures, pressures, pressure drops, corrosion, erosion, controllability requirements, or some combination thereof.
รับคำปรึกษาจากทีมงานเราได้ง่าย ทีมงานเรายินดีให้คำปรึกษา และจะติดต่อกลับโดยเร็วที่สุด..
เป็นผู้แทนจำหน่าย สินค้าชั้นนำทางด้านระบบส่องสว่าง ,เครื่องมือวัดและควบคุม ครบวงจร.